FIRE TECHNICS Ltd.

FIRE TECHNICS Ltd.

Google Follow us on Facebook Български
  • Home
  • About us
  • Products
  • Service
  • Engineering
  • Objects
  • Articles
  • Contacts
  • Home
  • Products
  • Fire alarm systems
  • Conventional panels
  • Fire Control Panel FS 5200
Menu
  • Fire extinguishers
  • Spare parts for extinguishers
  • Machines for charging fire extinguishers
  • Fire Fighting Equipment
  • Fire extinguishing systems
  • Fire gas extiguishing systems
  • Sprinkler systems
  • Aerosol extinguishing systems
  • Fire alarm systems
    • Interactive addressable system IFS 7000
    • Conventional panels
    • Conventional detectors
    • Addressable system FS 6000
  • Fire resistant doors
  • Fire protective clothing
  • Fire foam concentrates
  • Smoke vents
  • Active smoke curtains
  • Fixed smoke curtains
  • Fire curtains
  • Cylinders for technical gases
  • Extinguishing agents
  • Gas Detection Systems
  • Fire prevention systems
  • Fire protection of metal and wooden constructions
  • Emergency lighting
  • Safety signs
  • First Aid Kits, Safety Car Kits, Warning triangles, Safety vests

Fire Control Panel FS 5200

 
Technical data

FIRE ALARM LINES

- Maximum number of fire detectors in a line                                        32
     
- Connecting line                                                                        two-wire
   
- Maximum resistance of a line                                                         100Ω
   

CONTROLLABLE OUTPUTS
   


- Type Potential
   
- Electrical characteristics                                                              (24±5)V/500 mA
   

RELAY OUTPUTS FOR FAULT CONDITIONS                  

- Type potential                                                                           free, switching
    
- Electrical characteristics                                                      3 A/125 V AC; 3 A/30 V DC
   
RELAY OUTPUTS FOR FAULT CONDITIONS                 

 - Type potential                                                                       free, switching
   
-  Electrical characteristics                                                    3 A/125 V AC; 3 A/30 V DC
   
INDICATIONS OF REGISTERED EVENTS
   
- Light indication                                                                            LEDs
   
- Text messages                                       LCD display - 4 lines, 20 symbols,Latin/Cyrillic characters, backlit
   
- Sound                                                                               Built-in sounder
   
ACCESS LEVELS TO CONTROL FUNCTIONS                   4 (in compliance with EN 54/2)
   

POWER SUPPLY                   

- Voltage                                                                               220/230 V
   
- Frequency                                                                              50 Hz
   
BACKUP BATTERIES                                                            2 x 12 V / 12 Ah
   

OPERATION IN DUTY MODE UPON INTERRUPTED MAINS SUPPLY  
       

- Minimum configuration                                                                 80 h
   
- Maximum configuration                                                                30 h
   
CONSUMPTION ON BACKUP BATTERIES SUPPLY IN DUTY MODE AT 24 V
   


- Minimum configuration                                                             <155 mA
   
- Maximum configuration                                                            <400 mA
   
POWER SUPPLY TO EXTERNAL DEVICES
   
- Voltage                                                                                 (24±5)V
   
- Maximum current value (current of controllable outputs included)   1,5 A
   
WEIGHT (BACKUP BATTERIES NOT INCLUDED)                             6,6 kg
   
DIMENSIONS                                                                450 x 355 x 115mm
   
OPERATING TEMPERATURE                                            -5 oC to +40 oC
   
RELATIVE HUMIDITY                                                           to 93 %
   
DEGREE OF PROTECTION                                                     IP 40
   

 

Technical data

FIRE ALARM LINES

 

 

- Maximum number of fire detectors in a line               

32

 

- Connecting line

two-wire

 

- Maximum resistance of a line

100Ω

 

CONTROLLABLE OUTPUTS

 

 

- Type

Potential

 

- Electrical characteristics

(24±5)V/500 mA

 

RELAY OUTPUTS FOR FAULT CONDITIONS

 

- Type

potential free, switching

 

- Electrical characteristics

3 A/125 V AC; 3 A/30 V DC

 

RELAY OUTPUTS FOR FAULT CONDITIONS

 

- Type

potential free, switching

 

- Electrical characteristics

3 A/125 V AC; 3 A/30 V DC

 

INDICATIONS OF REGISTERED EVENTS

 

 

- Light indication

LEDs

 

- Text messages

LCD display - 4 lines, 20 symbols,

Latin/Cyrillic characters, backlit

 

- Sound

Built-in sounder

 

ACCESS LEVELS TO CONTROL FUNCTIONS

4 (in compliance with EN 54/2)

 

POWER SUPPLY

 

 

- Voltage

220/230 V

 

- Frequency

50 Hz

 

BACKUP BATTERIES

2 x 12 V / 12 Ah

 

OPERATION IN DUTY MODE UPON INTERRUPTED MAINS SUPPLY

 

- Minimum configuration

80 h

 

- Maximum configuration

30 h

 

CONSUMPTION ON BACKUP BATTERIES SUPPLY IN DUTY MODE AT 24 V

 

- Minimum configuration

<155 mA

 

- Maximum configuration

<400 mA

 

POWER SUPPLY TO EXTERNAL DEVICES

 

- Voltage

(24±5)V

 

- Maximum current value (current of controllable outputs included)

1,5 A

 

WEIGHT (BACKUP BATTERIES NOT INCLUDED)

6,6 kg

 

DIMENSIONS

450 x 355 x 115mm

 

OPERATING TEMPERATURE

-5 oC to +40 oC

 

RELATIVE HUMIDITY

to 93 %

 

DEGREE OF PROTECTION

IP 40

 

Partners