FIRE TECHNICS Ltd.

FIRE TECHNICS Ltd.

Google Follow us on Facebook Български
  • Home
  • About us
  • Products
  • Service
  • Engineering
  • Objects
  • Articles
  • Contacts
  • Home
  • Products
  • Fire alarm systems
  • Conventional panels
  • Fire Control Panel FS 4000/2/4/6/8 zones
Menu
  • Fire extinguishers
  • Spare parts for extinguishers
  • Machines for charging fire extinguishers
  • Fire Fighting Equipment
  • Fire extinguishing systems
  • Fire gas extiguishing systems
  • Sprinkler systems
  • Aerosol extinguishing systems
  • Fire alarm systems
    • Interactive addressable system IFS 7000
    • Conventional panels
    • Conventional detectors
    • Addressable system FS 6000
  • Fire resistant doors
  • Fire protective clothing
  • Fire foam concentrates
  • Smoke vents
  • Active smoke curtains
  • Fixed smoke curtains
  • Fire curtains
  • Cylinders for technical gases
  • Extinguishing agents
  • Gas Detection Systems
  • Fire prevention systems
  • Fire protection of metal and wooden constructions
  • Emergency lighting
  • Safety signs
  • First Aid Kits, Safety Car Kits, Warning triangles, Safety vests

Fire Control Panel FS 4000/2/4/6/8 zones

 
                   DESCRIPTION

Fire Control Panel FS 4000 is a modern, highly reliable, multifunctional and versatile product. It is designed to receive signals emitted by manual call points and automatic fire detectors, producing sound and light indication. The Fire Control Panel provides options for integration of external sound units and executive devices.

The Fire Control Panel is produced in four versions:

    * 2 fire alarm lines FS 4000/2
    * 4 fire alarm lines FS 4000/4
    * 6 fire alarm lines FS 4000/6
    * 8 fire alarm lines FS 4000/8

 

                 Functional data

- Control over fire alarm lines and controllable output for Fault conditions (Short circuit and Interruption) and automatic reset

- Detection of Removed fire detector and automatic reset

- Ability to identify automatic fire detectors and manual call points

- Delay option of 1,2,3,4 or 5 minutes for outputs

for Fire condition after Fire condition is registered.

- LED indication for Fire condition and Fault condition

- Built-in sound signalization for Fire condition

(one-tonal, continuous), that can be switched off

- Built-in sound signalization for Fault condition (one-tonal, discontinuous) that can be switched off

- Test mode of fire alarm lines

- Disable of fire alarm lines

- Disable of outputs for Fire condition

 
       Additional functional data of FS4000 new edition:

- There is one more controllable output, than the panel has complete 2 controllable outputs for FIRE.
-  There is connector and functions to join additional modul extention - FD4201, which include 2, 4, 6 or 8 relay outputs depend from the configuration, also RS485 interface for connection with other devices and networr.
-  There is jumper for disabling of fault Earth.

               Technical data


Description                                                                                      FS4000                              FS4000 new edition

FIRE ALARM LINES                                                                        2, 4, 6 or 8                                       2, 4, 6 or 8

maximum number of fire detectors in a line                                             32                                                   32

connecting line -                                                                            two-wire                                            two-wire

maximum resistance of a line                                                             100 Ω                                                100 Ω

CONTROLLABLE OUTPUT FOR FIRE CONDITION                                     1                                                       2

type                                                                                         potential, relay                                    potential, relay

electrical features                                                                      (19-24)VDC/0,45 A                               (19-24)VDC/1 A

RELAY OUTPUT FOR FIRE CONDITION                                                  1                                             No available

type                                                                                        potential-free, switching              potential-free, switching
    

electrical features                                                                              3 A / 30V DC                                  3 A / 30V DC
  
   
RELAY OUTPUT FOR FAULT CONDITION                                                1                                                         1

type                                                                                     potential-free, switching                  potential-free, switching

electrical features                                                                        3 A / 30V DC                                        3 A / 30V DC

SIGNALIZATION OF REGISTERED EVENTS
   
light                                                                                             LED                                                         LED

sound                                                                                     built-in sounder                                        built-in sounder

POWER SUPPLY
    
mains                                                                              (187-252)V AC, 50/60Hz                      (187-252)V AC, 50/60Hz

backup battery                                                                   1x12V DC, (3-7) Ah                          2x12V DC, (1,2-4,5)Ah,

                                                                                                                                              90x101x70mm


DURATION OF OPERATION IN DUTY MODE UPON INTERRUPTION OF MAINS SUPPLY
   

2 lines                                                                           80 h / 7 Ah   32 h / 3 Ah                                     120h/ 4.5Ah  32h/1.2Ah

4 lines                                                                           72 h / 7 Ah   30 h / 3 Ah                                       98h/ 4.5Ah  24h/1.2Ah

6 lines                                                                           60 h / 7 Ah   25 h / 3 Ah                                       80h/ 4.5Ah  20h/1.2Ah

8 lines                                                                           54 h / 7 Ah   22 h / 3 Ah                                       68h/ 4.5Ah  16h/1.2Ah

CONSUMPTION ON BACKUP BATTERIES SUPPLY IN DUTY MODE
   
FS 4000/2                                                                       < 85 mA / 12V DC                                      < 35 mA / 24 VDC

FS 4000/4                                                                       < 95 mA / 12V DC                                      < 45 mA / 24 VDC

FS 4000/6                                                                     < 110 mA / 12V DC                                      < 55 mA / 24 VDC

FS 4000/8                                                                     < 125 mA / 12V DC                                      < 65 mA / 24 VDC

AUXILIARY SUPPLY
   
voltage                                                                             (19-24)V DC                                                (19-24) VDC

maximum current (incl. current of controllable output)                0,45 A                                                         1,2 А

DIMENSIONS                                                                 313x218x85 mm                                          313x218x85 mm

WEIGHT (WITHOUT BACKUP BATTERY)                                1,5 kg                                                           2,5 kg

OPERATING TEMPERATURE    
                                        minus 5°C to 40°C                                       minus 5°C to 40°C

RELATIVE HUMIDITY                                                      (93±3)% at 40°C                                         (93±3)% at 40°C

DEGREE OF PROTECTION  
                                                  IP 40                                                               IP 40
Partners
© 2011 FIRE TECHNICS Ltd. Sitemap
by Stenik optimization and Wed design Stenik